Bakers Pride Oven FH-28 User Manual

Browse online or download User Manual for Deep fryers Bakers Pride Oven FH-28. Bakers Pride Oven FH-28 User's Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Ventless Hood System

Ventless Hood System MODEL FH-28 Installation & Operation Manual Serial Numbers 123046 and higher

Page 2 - Warranty Information

Ventless Hood System Operation 8 Shut-Down Power to the appliance is turned off, when the hood is turned off. For proper operation, always tur

Page 3 - Table of Contents

Ventless Hood System Installation 9 Installation Unpacking and Handling Inspection for Shipping Damage YOU are responsible for filing all freight

Page 4 - Introduction

Ventless Hood System Installation 10 Leveling 1. Adjust the four feet provided on the bottom of the unit so there is a minimum of 6” clearance b

Page 5 - Protect Children

Ventless Hood System Installation 11 Securing Wall Mount After the hood has been located and leveled, secure to building by utilizing the .437 di

Page 6

Ventless Hood System Installation 12 Assembly and Mounting Fire Damper A UL Listed 165° F fusible link must be installed in the damper assembly l

Page 7 - UL Information

Ventless Hood System Installation 13 Particle/Odor Filter 1. Remove the filter from the plastic bag. 2. Open the filter door on the front of

Page 8 - Griddles Specifications

Ventless Hood System Installation 14 Appliance Restraining Device Install appliance-restraining device as shown in the figure below. In the eve

Page 9 - Operation

Ventless Hood System Installation 15 Fire Extinguishing System In the event of an appliance fire, serious injury, property damage or death coul

Page 10 - Cleaning

Ventless Hood System Installation 16 3. If required, connect the provided fire extinguishing system contacts for remote signaling (refer to the

Page 11 - Installation

Ventless Hood System Installation 17 The fire extinguishing system must be operative before the electrical system will function. Refer to the e

Page 12 - Leveling

Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the original purchaser that at time of shipment from the Co

Page 13 - Securing

Ventless Hood System Installation 18

Page 14 - Assembly and Mounting

Ventless Hood System Installation 19 Appliance Electrical Connection This connection is for appliances requiring a UL listed flexible conduit co

Page 15 - Particle/Odor Filter

Ventless Hood System Maintenance 20 Maintenance Electrocution could occur if this unit is hosed down with water. This unit is NOT designed for

Page 16 - Appliance Restraining Device

Ventless Hood System Maintenance 21 Cleaning the Grease Baffle 1. Shut down the unit. 2. Locate the thumbscrews and retaining frame at the to

Page 17 - Fire Extinguishing System

P.O. Box 80400, Simpsonville, S.C. 29680-0400, USA http://www.bkideas.com Made and printed i

Page 18

Ventless Hood System Table of Contents 1 Table of Contents Table of Contents...

Page 19

Ventless Hood System Introduction 2 Introduction Congratulations! You have chosen BKI’s Ventless Hood system, a state-of-the-art unit that filter

Page 20

Ventless Hood System Introduction 3 Specific Precautions Carbon monoxide poisoning will result from using this hood with any appliance that uti

Page 21

Ventless Hood System Introduction 4 Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your equipment

Page 22 - Maintenance

Ventless Hood System Introduction 5 UL Information Failure to adhere to building, fire and electrical codes during installation of this unit co

Page 23 - Cleaning the Grease Baffle

Ventless Hood System Introduction 6 Fryers Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 60 Maximum Input 22 KW (3ph) 14.4 KW (1

Page 24

Ventless Hood System Operation 7 Operation Principle of Operation A blower inside the ventless hood draws cooking vapors through a grease baffle.

Comments to this Manuals

No comments